- Date
- 08/09/2022
- W/O
- 967221
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00031
- PipeID
- P11330
- Time
- 1:54 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10270
- Sewer Name
- E JOINT OUTFALL E - UNIT 4 RELOCATION
- City
- WATTS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- RFIR_WO_967221_TV01285_AUG2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Width
- 30 in.
- Upstream MH
- E 0102
- Downstream MH
- E 0103
- Dir. of Survey
- Upstream
- Length Surveyed
- 69.2 ft.
- Total Length
- 69.2 ft.
- Structural Index
- 3
- Structural Quick
- 5131
- Structural Rating
- 10
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 10
Pipe schematic from manhole E 0102 to E 0103 Observation photos (3)

2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.1 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start