Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 4, 2022, 05:02 AM
  • 02 2003_02 2002_08032022_220941.mp4

Date
08/03/2022
W/O
967261
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00260
PipeID
P04358
Time
10:02 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10311
Sewer Name
02 EAST COMPTON BOULEVARD RELIEF TRUNK #2
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_967261_TV02345_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
8 in.
Upstream MH
02 2003
Downstream MH
02 2002
Dir. of Survey
Downstream
Length Surveyed
54.3 ft.
Total Length
54.3 ft.
Structural Index
3
Structural Quick
4336
Structural Rating
32
O&M Index
2
O&M Quick
2A00
O&M Rating
20
Overall Index
3
Overall Quick
Overall Rating
52
Pipe schematic from manhole 02 2003 to 02 2002
MH: 02 2003MH: 02 2002downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 20032 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start12.4 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start42.9 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Finish42.9 ft. FH2 - Fracture Longitudinal Hinge, 2, from 03 to 09 o'clock, within 8 inches of joint: YES47.6 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start53.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish53.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish54.3 ft. MGO - General Observation - COCKROACHES IN MANHOLE54.3 ft. AMH - Downstream Manhole, Survey Ends - 02 2002

Observation photos (6)

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    2 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

    12.4 ft. - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal Hinge, 2, from 03 to 09 o'clock, within 8 inches of joint: YES

    42.9 ft. - Fracture Longitudinal Hinge, 2, from 03 to 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    47.6 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    54.3 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (13)

DistanceCodeObservation
53.1DAGS
12.4CM
0MWM
54.3MGOCOCKROACHES IN MANHOLE
53.1FM
42.9CM
0MWL
0AMH02 2003
2CL
2DAGS
42.9FH2
47.6FM
54.3AMH02 2002

Properties (8)

additional_info
630098080322201
custom_field_three
FRACTURES/CRACKS
custom_field_two
2
customer
1
datetime
2022-08-03T22:02:36-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
27557