Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 7, 2022, 09:37 AM
  • 03 0525_03 0524_07072022_024648.mp4

Date
07/07/2022
W/O
961997
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00367
PipeID
P05222
Time
2:37 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10254
Sewer Name
03 LOS COYOTES DIAGONAL RELIEF TRUNK
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
13
Purpose
Routine Assessment
Project
WO_961997_TV03101_JUL2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
03 0525
Downstream MH
03 0524
Dir. of Survey
Downstream
Length Surveyed
283.3 ft.
Total Length
283.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2J00
O&M Rating
110
Overall Index
2
Overall Quick
Overall Rating
113
Pipe schematic from manhole 03 0525 to 03 0524
MH: 03 0525MH: 03 0524downstream0 ft. AMH - Upstream Manhole, Survey Begins - 03 05250 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start248 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES281 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish283.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK283.3 ft. AMH - Downstream Manhole, Survey Ends - 03 0524

Observation photos (1)

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    248 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
0AMH03 0525
283.3MGOCONNECTION AT MH 3 O'CLOCK
248FL
281DAGS
283.3AMH03 0524
5DAGS
0MWL
0MWM

Properties (8)

additional_info
630074070622202
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2022-07-07T02:37:47-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
30845