Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 13, 2022, 10:06 AM
  • 22 1457_22 1084_07132022_032232.mp4

Date
07/13/2022
W/O
962009
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00812
PipeID
P17458
Time
3:06 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10229
Sewer Name
22 IRWINDALE TRUNK, SECTS 2,3,4,&5
City
IRWINDALE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_962009_TV22043_JUL2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 1084
Downstream MH
22 1457
Dir. of Survey
Upstream
Length Surveyed
316.5 ft.
Total Length
316.5 ft.
Structural Index
3
Structural Quick
3G00
Structural Rating
123
O&M Index
2
O&M Quick
2L00
O&M Rating
126
Overall Index
2
Overall Quick
Overall Rating
249
Pipe schematic from manhole 22 1084 to 22 1457
MH: 22 1084MH: 22 1457upstream0 ft. AMH - Upstream Manhole, Survey Ends - 22 14570 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK1.5 ft. CM - Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES, Finish1.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish73.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"96.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"166.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"179 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"202 ft. CM - Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES, Start217.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"227.7 ft. TBA - Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"231.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"268.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES300.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"303.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"310 ft. TBA - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: YES, 6"314.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start316.5 ft. MWL - Water Level, 5 %of cross sectional area316.5 ft. AMH - Downstream Manhole, Survey Begins - 22 1084316.5 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    48 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES, Start

    114.5 ft. - Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    316.5 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (21)

DistanceCodeObservation
137.5TFC
0MWL
315CM
0AMH22 1084
0MWM
2DAGS
316.5AMH22 1457
88.8TBA
85.4TFC
316.5MGOCOCKROACHES IN MANHOLE
219.9TFC
243.1TFC
16.2TFC
150.3TFC
114.5CM
6.5TBA
316.5MGOCONNECTION AT MH 3 O'CLOCK
13.2TFC
315DAGS
98.6TF
48CM

Properties (7)

additional_info
630098071222201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-07-13T03:06:48-07:00
documentation
PRO PIPE
is_lateral_inspection
false