- Date
- 07/13/2022
- W/O
- 962009
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00812
- PipeID
- P17452
- Time
- 1:56 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10228
- Sewer Name
- 22 IRWINDALE TRUNK, SECTS 2,3,4,&5
- City
- IRWINDALE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 18
- Purpose
- Capital Improvement Program Assesment
- Project
- RFIR_WO_962009_TV22043_JUL2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 22 1079
- Downstream MH
- 22 1078
- Dir. of Survey
- Downstream
- Length Surveyed
- 414.7 ft.
- Total Length
- 414.7 ft.
- Structural Index
- 3
- Structural Quick
- 514C
- Structural Rating
- 267
- O&M Index
- 2
- O&M Quick
- 2O00
- O&M Rating
- 164
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 431
Pipe schematic from manhole 22 1079 to 22 1078 Observation photos (7)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES, Start

11.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

126.6 ft. - Fracture Multiple, from 07 to 02 o'clock, within 8 inches of joint: YES

323.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

331.3 ft. - Hole, from 10 to 02 o'clock, within 8 inches of joint: YES

414.7 ft. - General Observation - COCKROACHES IN MANHOLE