J 0007_J 0006_07292022_004120.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - General Observation - MAG COATING
58.4 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 8"
74.2 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 8"
237.9 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 8" - ACTIVE CONNECTION.
237.9 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 12"
259.3 ft. - Tap Break-In Intruding, at 10 o'clock, -, #v, within 8 inches of joint: NO, 10", 2"
388.8 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 8"
| Distance | Code | Observation |
|---|---|---|
| 2 | SSS | — |
| 0 | MGO | ACTIVE CONNECTION AT MH 9 O'CLOCK. |
| 58.4 | TB | — |
| 259.3 | TBI | — |
| 422.1 | AMH | J 0006 |
| 422.1 | SSS | — |
| 0 | AMH | J 0007 |
| 0 | MWM | — |
| 74.2 | TB | — |
| 237.9 | TB | ACTIVE CONNECTION. |
| 2 | MGO | MAG COATING |
| 0 | MWL | — |
| 237.9 | TB | — |
| 388.8 | TBA | — |