Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 2, 2022, 04:43 AM
  • J 0003A_J 0003_08012022_230432.mp4

Date
08/01/2022
W/O
962251
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00060
PipeID
P11591
Time
9:43 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10259
Sewer Name
J JOINT OUTFALL J - UNIT 2A
City
HARBOR CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_962251_TV08100_JUL2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Width
57 in.
Upstream MH
J 0003A
Downstream MH
J 0003
Dir. of Survey
Downstream
Length Surveyed
1052.9 ft.
Total Length
1052.9 ft.
Structural Index
3
Structural Quick
573i
Structural Rating
1085
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
1085
Pipe schematic from manhole J 0003A to J 0003
MH: J 0003AMH: J 0003downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 0003A2 ft. MGO - General Observation - MAG COATING2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start281.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"579.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"615.5 ft. MGO - General Observation - POSSIBLE BROKEN, HANGING REINFORCEMENT (MAG COATED) - 9 TO 10 O'CLOCK.992.3 ft. MGO - General Observation - POSSIBLE BROKEN, HANGING REINFORCEMENT @ 3 O'CLOCK.1002.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"1020 ft. SRV - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - "MIXED" - CORRODED / COATED.1052.9 ft. SRV - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES, Finish1052.9 ft. MGO - General Observation - no mh J 0003 WENT TO J 00021052.9 ft. AMH - Downstream Manhole, Survey Ends - J 00021052.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1052.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1052.9 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 12 O'CLOCK.

Observation photos (2)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (18)

DistanceCodeObservation
0MWM
1002.7TFA
281.2TFA
1052.9SRV
2MGOMAG COATING
0MWL
0AMHJ 0003A
615.5MGOPOSSIBLE BROKEN, HANGING REINFORCEMENT (MAG COATED) - 9 TO 10 O'CLOCK.
1052.9MGOno mh J 0003 WENT TO J 0002
2SSS
2SAP
579.4TFA
1020SRV"MIXED" - CORRODED / COATED.
1052.9AMHJ 0002
992.3MGOPOSSIBLE BROKEN, HANGING REINFORCEMENT @ 3 O'CLOCK.
1052.9SSS
1052.9SAP
1052.9MGOACTIVE CONNECTION AT MH 12 O'CLOCK.

Properties (7)

additional_info
630098080122201
custom_field_three
AGGREGATE PROJECTING, SPALLING
custom_field_two
3
customer
1
datetime
2022-08-01T21:43:08-07:00
documentation
PRO PIPE
is_lateral_inspection
false