- Date
- 07/22/2022
- W/O
- 961788
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00700
- PipeID
- P14786
- Time
- 1:55 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10242
- Sewer Name
- 18 SCOTT AVENUE TRUNK
- City
- WHITTIER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_961788_TV18047_JUL2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- 18 0938
- Downstream MH
- 18 0937
- Dir. of Survey
- Downstream
- Length Surveyed
- 55.3 ft.
- Total Length
- 55.3 ft.
- Structural Index
- 3
- Structural Quick
- 3321
- Structural Rating
- 11
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 13
Pipe schematic from manhole 18 0938 to 18 0937 Observation photos (7)

0 ft. - General Observation - COCKROACHES IN MH

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

8.4 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: NO

19.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

44 ft. - Fracture Spiral, from 06 to 09 o'clock, within 8 inches of joint: YES

49.9 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

55.3 ft. - General Observation - COCKROACHES IN MH