Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 22, 2022, 07:24 AM
  • 18 0932_18 0931_07222022_004021.mp4

Date
07/22/2022
W/O
961788
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00700
PipeID
P14780
Time
12:24 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10242
Sewer Name
18 SCOTT AVENUE TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_961788_TV18047_JUL2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 0932
Downstream MH
18 0931
Dir. of Survey
Downstream
Length Surveyed
264.4 ft.
Total Length
264.4 ft.
Structural Index
4
Structural Quick
4332
Structural Rating
18
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
24
Pipe schematic from manhole 18 0932 to 18 0931
MH: 18 0932MH: 18 0931downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. AMH - Upstream Manhole, Survey Begins - 18 09322 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start8.2 ft. FM - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES17.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start36.8 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"39.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"70.5 ft. TBA - Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"83.5 ft. FM - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES84.6 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"87.2 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"135.6 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"137.3 ft. CM - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES138.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"160.3 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"186.2 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"187.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES189 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"234.2 ft. TBA - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"236.7 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"262.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish262.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish264.4 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK264.4 ft. AMH - Downstream Manhole, Survey Ends - 18 0931

Observation photos (7)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

    8.2 ft. - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    17.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

    83.5 ft. - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

    137.3 ft. - Crack Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    187.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (27)

DistanceCodeObservation
17.4CM
2DAGS
8.2FM
262.5CM
189TFC
70.5TBA
84.6TFA
83.5FM
36.8TFC
0MWL
87.2TFC
135.6TFC
160.3TBA
187.8FM
236.7TFA
0MWM
234.2TBA
0MGOCONNECTION AT MH 9 O'CLOCK
264.4MGOCONNECTION AT MH 9 O'CLOCK
138.1TFC
39.1TFC
262.5DAGS
186.2TFC
0MGOCOCKROACHES IN MH
264.4AMH18 0931
137.3CM
0AMH18 0932

Properties (7)

additional_info
630074072122202
custom_field_three
FRACTURES/CRACKS
custom_field_two
2
customer
1
datetime
2022-07-22T00:24:14-07:00
documentation
PRO PIPE
is_lateral_inspection
false