- Date
- 08/08/2022
- W/O
- 966752
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00696
- PipeID
- P14527
- Time
- 11:29 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10318
- Sewer Name
- 18 PHOEBE AVENUE TRUNK
- City
- LA MIRADA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 35
- Purpose
- Routine Assessment
- Project
- RFIR_WO_966752_TV18169_AUG2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 18 0678
- Downstream MH
- 18 0677
- Dir. of Survey
- Downstream
- Length Surveyed
- 197.5 ft.
- Total Length
- 197.5 ft.
- Structural Index
- 3
- Structural Quick
- 3200
- Structural Rating
- 6
- O&M Index
- 2
- O&M Quick
- 312G
- O&M Rating
- 81
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 87
Pipe schematic from manhole 18 0678 to 18 0677 Observation photos (4)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

6.4 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

14.3 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

16.1 ft. - Roots Medium Connection, from 09 to 12 o'clock, 20 %, within 8 inches of joint: YES