Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2022, 07:22 AM
  • 18 0674_18 0673_08092022_003405.mp4

Date
08/09/2022
W/O
966752
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00696
PipeID
P14523
Time
12:22 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10318
Sewer Name
18 PHOEBE AVENUE TRUNK
City
LA MIRADA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_966752_TV18169_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0674
Downstream MH
18 0673
Dir. of Survey
Downstream
Length Surveyed
128.8 ft.
Total Length
128.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
412D
O&M Rating
54
Overall Index
2
Overall Quick
Overall Rating
57
Pipe schematic from manhole 18 0674 to 18 0673
MH: 18 0674MH: 18 0673downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 06740 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start74.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"93.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES127.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish128.8 ft. MGO - General Observation - CONNECTION AT MH 12 O'CLOCK128.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0673

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    93.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
0AMH18 0674
74.8TFC
128.8MGOCONNECTION AT MH 12 O'CLOCK
127.5DAGS
0MWL
2DAGS
93.5CM
128.8AMH18 0673
0MWM

Properties (7)

additional_info
630098080822001
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-08-09T00:22:47-07:00
documentation
PRO PIPE
is_lateral_inspection
false