Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2022, 08:18 AM
  • 18 0673_18 0672_08092022_012721.mp4

Date
08/09/2022
W/O
966752
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00696
PipeID
P14522
Time
1:18 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10318
Sewer Name
18 PHOEBE AVENUE TRUNK
City
LA MIRADA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_966752_TV18169_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0672
Downstream MH
18 0673
Dir. of Survey
Upstream
Length Surveyed
207.7 ft.
Total Length
207.7 ft.
Structural Index
3
Structural Quick
3G21
Structural Rating
116
O&M Index
2
O&M Quick
2G00
O&M Rating
82
Overall Index
2
Overall Quick
Overall Rating
198
Pipe schematic from manhole 18 0672 to 18 0673
MH: 18 0672MH: 18 0673upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 06730 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK2.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish190.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start205.4 ft. CS - Crack Spiral, from 12 to 04 o'clock, within 8 inches of joint: YES205.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start207.7 ft. AMH - Downstream Manhole, Survey Begins - 18 0672207.7 ft. MWM - Water Mark, 35 %of cross sectional area207.7 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Spiral, from 12 to 04 o'clock, within 8 inches of joint: YES

    2.3 ft. - Crack Spiral, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    17 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0AMH18 0672
2.3CS
204.9DAGS
2DAGS
207.7AMH18 0673
207.7MGOCONNECTION AT MH 3 O'CLOCK
0MWM
0MWL
204.9CM
17CM

Properties (7)

additional_info
630098080822001
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-08-09T01:18:18-07:00
documentation
PRO PIPE
is_lateral_inspection
false