Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2022, 08:05 AM
  • 18 0672_18 0671_08092022_011806.mp4

Date
08/09/2022
W/O
966752
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00696
PipeID
P14521
Time
1:05 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10318
Sewer Name
18 PHOEBE AVENUE TRUNK
City
LA MIRADA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_966752_TV18169_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0671
Downstream MH
18 0672
Dir. of Survey
Upstream
Length Surveyed
200.4 ft.
Total Length
200.4 ft.
Structural Index
3
Structural Quick
3222
Structural Rating
10
O&M Index
2
O&M Quick
2G00
O&M Rating
78
Overall Index
2
Overall Quick
Overall Rating
88
Pipe schematic from manhole 18 0671 to 18 0672
MH: 18 0671MH: 18 0672upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 06721.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish1.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish7.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start11.9 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES28.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"119.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"124.6 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"163.9 ft. CS - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES198.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start200.4 ft. MWM - Water Mark, 35 %of cross sectional area200.4 ft. MWL - Water Level, 5 %of cross sectional area200.4 ft. AMH - Downstream Manhole, Survey Begins - 18 0671

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    188.5 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
0MWM
75.8TFA
0MWL
193CM
2DAGS
198.9DAGS
172.3TFC
200.4AMH18 0672
188.5CL
80.8TFC
0AMH18 0671
36.5CS
198.9CM

Properties (7)

additional_info
630098080822001
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-08-09T01:05:33-07:00
documentation
PRO PIPE
is_lateral_inspection
false