Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2022, 10:36 AM
  • 18 0658_18 0657_08092022_035138.mp4

Date
08/09/2022
W/O
966752
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00696
PipeID
P14507
Time
3:36 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10318
Sewer Name
18 PHOEBE AVENUE TRUNK
City
LA MIRADA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_966752_TV18169_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
18 0658
Downstream MH
18 0657
Dir. of Survey
Downstream
Length Surveyed
302.2 ft.
Total Length
302.2 ft.
Structural Index
3
Structural Quick
3B23
Structural Rating
57
O&M Index
2
O&M Quick
2K00
O&M Rating
120
Overall Index
2
Overall Quick
Overall Rating
177
Pipe schematic from manhole 18 0658 to 18 0657
MH: 18 0658MH: 18 0657downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 06580 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start8.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"12.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"20.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: NO105.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"109.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"132.5 ft. RPL - Repair Localized Liner, within 8 inches of joint: YES, Start157.4 ft. RPL - Repair Localized Liner, within 8 inches of joint: YES, Finish189.4 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: NO205.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"208.9 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: NO210.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"213.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start300 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish300 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish302.2 ft. AMH - Downstream Manhole, Survey Ends - 18 0657

Observation photos (5)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Repair Localized Liner, within 8 inches of joint: YES, Start

    132.5 ft. - Repair Localized Liner, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: NO

    189.4 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: NO

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: NO

    208.9 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: NO

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    213.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
210.8TFC
2DAGS
157.4RPL
0MWL
205.1TFC
189.4CL
12.6TFC
20.5CL
208.9CL
302.2AMH18 0657
8.3TFA
0AMH18 0658
132.5RPL
300CM
300DAGS
105.1TFC
0MWM
213.8CM
109.2TFA

Properties (7)

additional_info
630098080822001
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-08-09T03:36:08-07:00
documentation
PRO PIPE
is_lateral_inspection
false