Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2022, 05:35 AM
  • 18 0828_18 0827_08092022_224630.mp4

Date
08/09/2022
W/O
966850
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00707
PipeID
P14691
Time
10:35 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10319
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 5
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_966850_TV18119_AUG2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0827
Downstream MH
18 0828
Dir. of Survey
Upstream
Length Surveyed
240 ft.
Total Length
240 ft.
Structural Index
4
Structural Quick
4D3C
Structural Rating
168
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
168
Pipe schematic from manhole 18 0827 to 18 0828
MH: 18 0827MH: 18 0828upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 08280 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish17.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"20.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"66.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"70 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"117 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"120.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"134.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start134.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish166.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"169.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"219.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"223 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"237 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start240 ft. MWM - Water Mark, 10 %of cross sectional area240 ft. MWL - Water Level, 5 %of cross sectional area240 ft. AMH - Downstream Manhole, Survey Begins - 18 0827

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    105.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (18)

DistanceCodeObservation
173.6TFC
73.4TFC
170TFC
0MWM
119.8TFC
240AMH18 0828
3CM
240FM
105.4FM
0MWL
105.4CM
219.7TFC
70.2TFC
222.7TFC
0AMH18 0827
20.3TFC
17TFC
123TFC

Properties (7)

additional_info
630098080922201
custom_field_three
MULTIPLE CRACKS
custom_field_two
2
customer
1
datetime
2022-08-09T22:35:20-07:00
documentation
PRO PIPE
is_lateral_inspection
false