- Date
- 07/22/2022
- W/O
- 962007
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00700
- PipeID
- P14781
- Time
- 12:08 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10241
- Sewer Name
- 18 SCOTT AVENUE TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_962007_TV18118_JUL2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- 18 0933
- Downstream MH
- 18 0932
- Dir. of Survey
- Downstream
- Length Surveyed
- 85.6 ft.
- Total Length
- 85.6 ft.
- Structural Index
- 3
- Structural Quick
- 4132
- Structural Rating
- 10
- O&M Index
- 3
- O&M Quick
- 4121
- O&M Rating
- 6
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 16
Pipe schematic from manhole 18 0933 to 18 0932 Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

5.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

33.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

48.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

85.6 ft. - General Observation - COCKROACHES IN MH