- Date
- 07/26/2022
- W/O
- 962010
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00886
- PipeID
- P19833
- Time
- 12:26 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10245
- Sewer Name
- 32 CASTAIC TRUNK
- City
- CASTAIC
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 32
- Page No.
- 01
- Purpose
- Routine Assessment
- Project
- RFIR_WO_962010_TV32047_JUL2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 32 0069
- Downstream MH
- 32 0068
- Dir. of Survey
- Downstream
- Length Surveyed
- 191.1 ft.
- Total Length
- 191.1 ft.
- Structural Index
- 4
- Structural Quick
- 4231
- Structural Rating
- 11
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 13
Pipe schematic from manhole 32 0069 to 32 0068 Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

67.6 ft. - Fracture Multiple, from 07 to 02 o'clock, within 8 inches of joint: YES

95.6 ft. - Repair Localized Liner, within 8 inches of joint: YES, Start

116.6 ft. - Fracture Spiral, from 09 to 03 o'clock, within 8 inches of joint: YES

147 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES