Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 12, 2022, 07:53 PM
  • H 0425_H 0424_08122022_134417.mp4

Date
08/12/2022
W/O
962020
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00613
PipeID
P10880
Time
12:53 PM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10362
Sewer Name
H JOINT OUTFALL H - UNIT 5D
City
SOUTH EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_962020_TV15263_JUL2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
15 in.
Upstream MH
H 0425
Downstream MH
H 0424
Dir. of Survey
Downstream
Length Surveyed
708.8 ft.
Total Length
708.8 ft.
Structural Index
3
Structural Quick
3[2[
Structural Rating
700
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
700
Pipe schematic from manhole H 0425 to H 0424
MH: H 0425MH: H 0424downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 04250 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK9.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start9.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start27.7 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"316.6 ft. MGO - General Observation - MAG COATING707.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish708.8 ft. AMH - Downstream Manhole, Survey Ends - H 0424, ZOOMED IN708.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    9.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    9.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
9.2SSS
707.9SSS
2.1MGOCONNECTION AT MH 3 O'CLOCK
27.7TBA
0AMHH 0425
708.8AMHH 0424, ZOOMED IN
9.2SAP
0MWL
0MWM
316.6MGOMAG COATING
708.8SAP

Properties (7)

additional_info
630098081222063
custom_field_three
SPALLING, AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2022-08-12T12:53:13-07:00
documentation
PRO PIPE
is_lateral_inspection
false