Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 27, 2022, 09:39 AM
  • 17 0083_17 0082_07272022_025412.mp4

Date
07/27/2022
W/O
962072
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00669
PipeID
P13801
Time
2:39 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10249
Sewer Name
17 LINCOLN AVENUE TRUNK
City
ALTADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_962072_TV17009_JUL2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
17 0083
Downstream MH
17 0082
Dir. of Survey
Downstream
Length Surveyed
183.7 ft.
Total Length
183.7 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 17 0083 to 17 0082
MH: 17 0083MH: 17 0082downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. AMH - Upstream Manhole, Survey Begins - 17 00830 ft. MWL - Water Level, 5 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start5.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start17.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"21.1 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"24.4 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"48.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"74.5 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"85.2 ft. RFJ - Roots Fine Joint, from 10 to 12 o'clock, within 8 inches of joint: YES110.7 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"126.1 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"149.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"181.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish181.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish183.7 ft. AMH - Downstream Manhole, Survey Ends - 17 0082183.7 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (4)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 10 to 12 o'clock, within 8 inches of joint: YES

    85.2 ft. - Roots Fine Joint, from 10 to 12 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
126.1TFC
85.2RFJ
0MWM
0MGOCOCKROACHES IN MH
24.4TFC
74.5TFC
0AMH17 0083
181.4DAGS
183.7AMH17 0082
17.7TF
181.4CM
149.9TFC
0MWL
48.1TFC
110.7TF
5.1CM
183.7MGOCONNECTION AT MH 9 O'CLOCK
21.1TB
2DAGS

Properties (7)

additional_info
630074072622203
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2022-07-27T02:39:58-07:00
documentation
PRO PIPE
is_lateral_inspection
false