Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 14, 2022, 06:05 AM
  • 03 0051_03 0050_07132022_232251.mp4

Date
07/13/2022
W/O
962049
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00366
PipeID
P05071
Time
11:05 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9979
Sewer Name
03 LOS COYOTES DIAGONAL TRUNK
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_962049_TV03117_JUL2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
03 0051
Downstream MH
03 0050
Dir. of Survey
Downstream
Length Surveyed
349.5 ft.
Total Length
349.6 ft.
Structural Index
3
Structural Quick
3221
Structural Rating
8
O&M Index
2
O&M Quick
2M00
O&M Rating
136
Overall Index
2
Overall Quick
Overall Rating
144
Pipe schematic from manhole 03 0051 to 03 0050
MH: 03 0051MH: 03 0050downstream0 ft. AMH - Upstream Manhole, Survey Begins - 03 00510 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area8.3 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start10 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6"10.5 ft. CM - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: NO82.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO82.4 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6"117.8 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"174 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"225.6 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"263.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES279.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"306.9 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"347.6 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish349.6 ft. AMH - Downstream Manhole, Survey Ends - 03 0050

Observation photos (11)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    8.3 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6"

    10 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6"

  • Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: NO

    10.5 ft. - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: NO

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO

    82.4 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6"

    82.4 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"

    117.8 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    174 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    225.6 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    263.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    279.5 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"

    306.9 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6", 6"

Observations (16)

DistanceCodeObservation
347.6DAE
10TB
82.4CL
0AMH03 0051
225.6TB
306.9TBA
174TB
8.3DAE
10.5CM
117.8TBA
349.6AMH03 0050
0MWM
279.5TB
263.8FL
82.4TB
0MWL

Properties (7)

additional_info
630074071322201
custom_field_three
ENCRUSTATION, CRACKS, FRACTURE
custom_field_two
3
customer
1
datetime
2022-07-13T23:05:35-07:00
documentation
PRO PIPE
is_lateral_inspection
false