Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 28, 2022, 09:21 AM
  • B 0404_B 0403_07282022_023233.mp4

Date
07/28/2022
W/O
962162
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00091
PipeID
P08916
Time
2:21 AM
Certificate
U-0720-70309212
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9998
Sewer Name
B JOINT OUTFALL B - UNIT 5A
City
ARCADIA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary
District
DISTRICT 15
Page No.
07
Purpose
Routine Assessment
Project
WO_962162_TV15047_JUL2022
Sewer Type
Gravity
Material
NRCP
Shape
Other
Height
21 in.
Upstream MH
B 0404
Downstream MH
B 0403
Dir. of Survey
Downstream
Length Surveyed
226.2 ft.
Total Length
226.2 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole B 0404 to B 0403
MH: B 0404MH: B 0403downstream0 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start0 ft. AMH - Upstream Manhole, Survey Begins - B 04040 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start14 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"30 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"53.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"118 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"125.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"165.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"176.5 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"182.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"213.7 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"224.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish224.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish224.2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish226.2 ft. MGO - General Observation - COCKROACHES IN MH226.2 ft. AMH - Downstream Manhole, Survey Ends - B 0403

Observation photos (5)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    0 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MH

    226.2 ft. - General Observation - COCKROACHES IN MH

Observations (21)

DistanceCodeObservation
0SSS
224.2DAGS
165.9TF
213.7TFA
125.5TFA
226.2MGOCOCKROACHES IN MH
182.1TFC
2DAGS
0AMHB 0404
53.6TFA
0MWL
0MGOCOCKROACHES IN MH
30TF
14TFA
226.2AMHB 0403
118TF
0MWM
176.5TFA
224.2SSS
224.2SAV
2SAV

Properties (7)

additional_info
630074072722203
custom_field_three
VISIBLE AGGREGATE/SPALLING
custom_field_two
3
customer
LACSD
datetime
2022-07-28T02:21:40-07:00
documentation
PRO PIPE
is_lateral_inspection
false