- Date
- 08/15/2022
- W/O
- 961757
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00181
- PipeID
- P10912
- Time
- 8:28 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K10363
- Sewer Name
- H JOINT OUTFALL H - UNIT 6
- City
- CITY OF INDUSTRY
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 29
- Purpose
- Routine Assessment
- Project
- RFIR_WO_961757_TV15212_JUL2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 54 in.
- Width
- 54 in.
- Upstream MH
- H 0486
- Downstream MH
- H 0485
- Dir. of Survey
- Downstream
- Length Surveyed
- 451.2 ft.
- Total Length
- 451.2 ft.
- Structural Index
- 3
- Structural Quick
- 3Q2Q
- Structural Rating
- 448
- O&M Index
- 1
- O&M Quick
- 2115
- O&M Rating
- 7
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 455
Pipe schematic from manhole H 0486 to H 0485 Observation photos (4)

3.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

3.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

108.9 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 02 to 05 o'clock, , within 8 inches of joint: NO

424.2 ft. - Alignment Left, 10 %, Start