Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 26, 2022, 09:01 AM
  • 30 0243_30 0242_8262022_023014.mp4

Date
08/26/2022
W/O
0967059
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00884
PipeID
P17944
Time
2:01 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3185
Sewer Name
30 VIA CAMPESINA TRUNK
City
PALOS VERDES
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
09
Purpose
Capital Improvement Program Assesment
Project
20220826_SHO_VIA_CMP_TR
Material
NRCP
Shape
Circular
Height
10 in.
Upstream MH
30 0243
Downstream MH
30 0242
Dir. of Survey
Downstream
Length Surveyed
230.4 ft.
Total Length
230.4 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
3
O&M Quick
3623
O&M Rating
25
Overall Index
3
Overall Quick
Overall Rating
30
Pipe schematic from manhole 30 0243 to 30 0242
MH: 30 0243MH: 30 0242downstream0 ft. AMH - Upstream Manhole, Survey Begins - MH 02430 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start11.7 ft. RFJ - Roots Fine Joint, from 07 to 05 o'clock, within 8 inches of joint: YESR, Start26.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"49.7 ft. RML - Roots Medium Lateral, from 08 to 10 o'clock, 10 %, within 8 inches of joint: YES51.2 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - FULL OF ROOTS72.7 ft. RMJ - Roots Medium Joint, from 04 to 05 o'clock, 5 %, within 8 inches of joint: YESR74.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"75.7 ft. RMJ - Roots Medium Joint, from 07 to 05 o'clock, 10 %, within 8 inches of joint: YESR106.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"172.1 ft. RMJ - Roots Medium Joint, from 04 to 05 o'clock, 10 %, within 8 inches of joint: YESR180.5 ft. RMJ - Roots Medium Joint, from 04 to 05 o'clock, 10 %, within 8 inches of joint: YESR202.4 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 4" - LARGE TAP ROOT202.4 ft. RTL - Roots Tap Lateral, from 07 to 09 o'clock, 20 %, within 8 inches of joint: YES224.1 ft. RMJ - Roots Medium Joint, from 07 to 05 o'clock, 10 %, within 8 inches of joint: YESR224.1 ft. RFJ - Roots Fine Joint, from 07 to 05 o'clock, within 8 inches of joint: YESR, Finish230.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish230.4 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish230.4 ft. AMH - Downstream Manhole, Survey Ends - MH 242

Observations (22)

DistanceCodeObservation
202.4TFDLARGE TAP ROOT
75.7RMJ
72.7RMJ
49.7RML
0AMHMH 0243
230.4SSS
11.7RFJ
202.4RTL
106.4TF
230.4SAP
51.2TFDFULL OF ROOTS
180.5RMJ
74.3TFC
0MWM
172.1RMJ
3SSS
26.2TFC
0MWL
230.4AMHMH 242
3SAP
224.1RMJ
224.1RFJ

Properties (7)

additional_info
RFIR
custom_field_three
RFIR
custom_field_two
2
customer
LACSD
datetime
2022-08-26T02:01:21-07:00
documentation
OBREGON, CASTILLO, OLIVER
is_lateral_inspection
false