Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 22, 2022, 06:36 AM
  • 08 0220_08 0219_06222022_005036.mp4

Date
06/21/2022
W/O
957403
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00005
PipeID
P00090
Time
11:36 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10186
Sewer Name
08 EAST ROAD TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_957403_TV08013_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
08 0220
Downstream MH
08 0219
Dir. of Survey
Downstream
Length Surveyed
162.5 ft.
Total Length
162.5 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 08 0220 to 08 0219
MH: 08 0220MH: 08 0219downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 02203.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start15.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"61.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"135.2 ft. RFJ - Roots Fine Joint, from 07 to 05 o'clock, within 8 inches of joint: YES136.7 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"160.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish162.5 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK162.5 ft. AMH - Downstream Manhole, Survey Ends - 05 0219

Observation photos (3)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    15.3 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Roots Fine Joint, from 07 to 05 o'clock, within 8 inches of joint: YES

    135.2 ft. - Roots Fine Joint, from 07 to 05 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
0MWL
0MWM
0AMH08 0220
162.5MGOCONNECTION AT MH 3 O'CLOCK
136.7TB
3.8FM
15.3TB
61.1TFC
160.7FM
135.2RFJ
162.5AMH05 0219

Properties (7)

additional_info
630074062122202
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-06-21T23:36:06-07:00
documentation
PROPIPE
is_lateral_inspection
false