Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 14, 2022, 02:10 PM
  • H 0677_H 0676_06142022_081811.mp4

Date
06/14/2022
W/O
951829
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00941
PipeID
P11084
Time
7:10 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10169
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
PICO RIVERA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_951829_TV18175_MAY2022
Sewer Type
Siphon
Material
NRCP
Shape
Circular
Height
25 in.
Width
25 in.
Upstream MH
H 0677
Downstream MH
H 0676
Dir. of Survey
Downstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole H 0677 to H 0676
MH: H 0677MH: H 0676downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 06770 ft. MWL - Water Level, 80 %of cross sectional area0 ft. MWM - Water Mark, 95 %of cross sectional area2.1 ft. MSA - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH2.1 ft. FS - Fracture Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES2.1 ft. MMC - Material Change, Vitrified clay pipe

Observation photos (2)

  • Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

    2.1 ft. - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

  • Fracture Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES

    2.1 ft. - Fracture Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (6)

DistanceCodeObservation
0AMHH 0677
2.1MSAVIEW OF D/S SIPHON FROM U/S MH
2.1FS
2.1MMC
0MWL
0MWM

Properties (8)

additional_info
630074061422061
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-06-14T07:10:14-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
30630