Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 10, 2022, 03:25 PM
  • H 0703_H 0702_06102022_105024.mp4

Date
06/10/2022
W/O
951829
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00941
PipeID
P11110
Time
8:25 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10167
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
PICO RIVERA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_951829_TV18175_MAY2022
Sewer Type
Siphon
Material
NRCP
Shape
Circular
Height
25 in.
Width
25 in.
Upstream MH
H 0702
Downstream MH
H 0703
Dir. of Survey
Upstream
Length Surveyed
6.5 ft.
Total Length
6.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole H 0702 to H 0703
MH: H 0702MH: H 0703upstream0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. MSA - Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH4.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.5 ft. MWL - Water Level, 15 %of cross sectional area6.5 ft. MWM - Water Mark, 20 %of cross sectional area6.5 ft. AMH - Downstream Manhole, Survey Begins - H 0702

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH

    6.5 ft. - Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH

Observations (6)

DistanceCodeObservation
6.5SAV
2.1SAV
0MWL
0MWM
0AMHH 0702
6.5MSAVIEW OF U/S SIPHON FROM D/S MH

Properties (7)

additional_info
630074061022061
custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2022-06-10T08:25:56-07:00
documentation
PROPIPE
is_lateral_inspection
false