Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 6, 2022, 08:39 AM
  • H 0676_H 0675_05062022_025303.mp4

Date
05/06/2022
W/O
951829
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00941
PipeID
P11083
Time
1:39 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10091
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
PICO RIVERA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_951829_TV18175_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
25 in.
Width
25 in.
Upstream MH
H 0676
Downstream MH
H 0675
Dir. of Survey
Downstream
Length Surveyed
623.1 ft.
Total Length
623.1 ft.
Structural Index
3
Structural Quick
3X00
Structural Rating
372
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
372
Pipe schematic from manhole H 0676 to H 0675
MH: H 0676MH: H 0675downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 06760 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start623.1 ft. AMH - Downstream Manhole, Survey Ends - H 0674623.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish623.1 ft. MGO - General Observation - H 0675 DOESN'T EXIST.

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
623.1AMHH 0674
0AMHH 0676
0MWM
623.1SAV
2.1SAV
0MWL
623.1MGOH 0675 DOESN'T EXIST.

Properties (7)

additional_info
630074050522201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-05-06T01:39:14-07:00
documentation
PROPIPE
is_lateral_inspection
false