Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 7, 2022, 05:33 AM
  • H 0668_H 0667_07062022_234904.mp4

Date
07/06/2022
W/O
951829
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00941
PipeID
P11075
Time
10:33 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10253
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
PICO RIVERA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_951829_TV18175_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
28 in.
Width
28 in.
Upstream MH
H 0668
Downstream MH
H 0667
Dir. of Survey
Downstream
Length Surveyed
547.5 ft.
Total Length
547.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole H 0668 to H 0667
MH: H 0668MH: H 0667downstream0 ft. MGO - General Observation - ABANDONED MH0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 06682.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start37.3 ft. MGO - General Observation - ABANDONED MH547.5 ft. MGO - General Observation - MOBILE MMS - 545.30'547.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish547.5 ft. AMH - Downstream Manhole, Survey Ends - H 0667

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
0MGOABANDONED MH
2.7SAV
37.3MGOABANDONED MH
547.5MGOMOBILE MMS - 545.30'
547.5SAV
0MWM
0MWL
0AMHH 0668
547.5AMHH 0667

Properties (7)

additional_info
630074070622201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-07-06T22:33:06-07:00
documentation
PROPIPE
is_lateral_inspection
false