Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 6, 2022, 06:22 AM
  • H 0698_H 0697_05062022_004251.mp4

Date
05/05/2022
W/O
951829
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00941
PipeID
P11105
Time
11:22 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10091
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_951829_TV18175_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
25 in.
Width
25 in.
Upstream MH
H 0697
Downstream MH
H 0698
Dir. of Survey
Upstream
Length Surveyed
721.5 ft.
Total Length
721.5 ft.
Structural Index
3
Structural Quick
3\00
Structural Rating
429
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
429
Pipe schematic from manhole H 0697 to H 0698
MH: H 0697MH: H 0698upstream0 ft. AMH - Upstream Manhole, Survey Ends - H 06980 ft. MGO - General Observation - MOBILE MMS - 722.50'2.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish719.4 ft. MGO - General Observation - MAG COAT719.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start721.5 ft. AMH - Downstream Manhole, Survey Begins - H 0697721.5 ft. MWL - Water Level, 15 %of cross sectional area721.5 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
718.9SAV
2.1MGOMAG COAT
0AMHH 0697
721.5AMHH 0698
2.1SAV
721.5MGOMOBILE MMS - 722.50'
0MWL
0MWM

Properties (7)

additional_info
630074050522201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-05-05T23:22:36-07:00
documentation
PROPIPE
is_lateral_inspection
false