Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 10, 2022, 06:07 PM
  • H 0693_H 0692_06102022_124047.mp4

Date
06/10/2022
W/O
951829
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00941
PipeID
P11100
Time
11:07 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10167
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
WHITTIER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_951829_TV18175_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
25 in.
Width
25 in.
Upstream MH
H 0692
Downstream MH
H 0693
Dir. of Survey
Upstream
Length Surveyed
754.6 ft.
Total Length
754.6 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole H 0692 to H 0693
MH: H 0692MH: H 0693upstream0 ft. AMH - Upstream Manhole, Survey Ends - H 06930.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish102.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"752.5 ft. MGO - General Observation - MAG COAT752.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start754.6 ft. MWM - Water Mark, 20 %of cross sectional area754.6 ft. AMH - Downstream Manhole, Survey Begins - H 0692754.6 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWM
0AMHH 0692
2.1MGOMAG COAT
0MWL
754.4SAV
2.1SAV
651.9TF
754.6AMHH 0693

Properties (7)

additional_info
630074061022061
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-06-10T11:07:59-07:00
documentation
PROPIPE
is_lateral_inspection
false