Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 6, 2022, 09:19 AM
  • H 0677_H 0676_05062022_032249.mp4

Date
05/06/2022
W/O
951829
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00941
PipeID
P11084
Time
2:19 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10091
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
PICO RIVERA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_951829_TV18175_MAY2022
Sewer Type
Siphon
Material
NRCP
Shape
Circular
Height
25 in.
Width
25 in.
Upstream MH
H 0676
Downstream MH
H 0677
Dir. of Survey
Upstream
Length Surveyed
61.2 ft.
Total Length
61.2 ft.
Structural Index
3
Structural Quick
3A00
Structural Rating
36
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
36
Pipe schematic from manhole H 0676 to H 0677
MH: H 0676MH: H 0677upstream0 ft. MSA - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish59.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start61.2 ft. AMH - Downstream Manhole, Survey Begins - H 067661.2 ft. MWL - Water Level, 10 %of cross sectional area61.2 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON

    61.2 ft. - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON

Observations (6)

DistanceCodeObservation
0AMHH 0676
0MWL
61.2MSAVIEW OF UPLEG OF D/S SIPHON
61.2SAV
2.1SAV
0MWM

Properties (8)

additional_info
630074050522201
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-05-06T02:19:13-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
30630