Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 8, 2022, 08:06 AM
  • 08 0231_08 0230_07082022_013657.mp4

Date
07/08/2022
W/O
962037
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00005
PipeID
P00105
Time
1:06 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9974
Sewer Name
08 EAST ROAD TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_962037_TV08112_JUL2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
12 in.
Upstream MH
08 0230
Downstream MH
08 0231
Dir. of Survey
Upstream
Length Surveyed
349.8 ft.
Total Length
349.8 ft.
Structural Index
4
Structural Quick
4M00
Structural Rating
276
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
276
Pipe schematic from manhole 08 0230 to 08 0231
MH: 08 0230MH: 08 0231upstream0 ft. MGO - General Observation - CONNECTION AT MH BOTH 3 & 9 O'CLOCK0 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 08 023173.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8"77.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"132.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 8"238.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8"333.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8"344.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start349.8 ft. MWL - Water Level, 50 %of cross sectional area349.8 ft. MWL - Water Level, 30 %of cross sectional area349.8 ft. AMH - Downstream Manhole, Survey Begins - 08 0230

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
5.1FM
0MWL
272.2TFC
111.2TF
217.1TFA
0MWL
349.8MGOCONNECTION AT MH BOTH 3 & 9 O'CLOCK
349.8FM
276TF
0AMH08 0230
349.8AMH08 0231
16.4TF

Properties (7)

additional_info
630063070722201
custom_field_three
FRACTURES
custom_field_two
2
customer
1
datetime
2022-07-08T01:06:57-07:00
documentation
PRO PIPE
is_lateral_inspection
false