- Date
- 06/24/2022
- W/O
- 956992
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00616
- PipeID
- P12621
- Time
- 12:26 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10206
- Sewer Name
- 15 MONROVIA OUTFALL TRUNK
- City
- MONROVIA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- WO_956992_TV15131_JUN2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- 15 0728
- Downstream MH
- 15 0727
- Dir. of Survey
- Downstream
- Length Surveyed
- 457.5 ft.
- Total Length
- 457.5 ft.
- Structural Index
- 4
- Structural Quick
- 5Q3Q
- Structural Rating
- 819
- O&M Index
- 2
- O&M Quick
- 3E2Q
- O&M Rating
- 272
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 1091
Pipe schematic from manhole 15 0728 to 15 0727 Observation photos (6)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

6.8 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

213.6 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

457.5 ft. - General Observation - COCKROACHES IN MANHOLE