Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 24, 2022, 05:52 AM
  • 15 0723_15 0722_06242022_000116.mp4

Date
06/23/2022
W/O
956992
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00616
PipeID
P12616
Time
10:52 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10206
Sewer Name
15 MONROVIA OUTFALL TRUNK
City
MONROVIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
09
Purpose
Routine Assessment
Project
WO_956992_TV15131_JUN2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
15 0723
Downstream MH
15 0722
Dir. of Survey
Downstream
Length Surveyed
53.9 ft.
Total Length
53.9 ft.
Structural Index
4
Structural Quick
5A3A
Structural Rating
80
O&M Index
2
O&M Quick
2A00
O&M Rating
20
Overall Index
3
Overall Quick
Overall Rating
100
Pipe schematic from manhole 15 0723 to 15 0722
MH: 15 0723MH: 15 0722downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 07230 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2.3 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start16.2 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"53.2 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish53.2 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"53.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish53.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish53.9 ft. AMH - Downstream Manhole, Survey Ends - 15 072253.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE53.9 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (5)

  • General Observation - CONNECTION AT MH 3 O'CLOCK

    0 ft. - General Observation - CONNECTION AT MH 3 O'CLOCK

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    53.9 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (16)

DistanceCodeObservation
2DAGS
53.9AMH15 0722
53.2SRV
0AMH15 0723
0MGOCONNECTION AT MH 3 O'CLOCK
16.2TBA
2.3SRV
53.2TB
0MWM
0MWL
53.2SAP
2SAP
0MGOCOCKROACHES IN MANHOLE
53.9MGOCOCKROACHES IN MANHOLE
53.9MGOCONNECTION AT MH 9 O'CLOCK
53.2DAGS

Properties (7)

additional_info
630098062322201
custom_field_three
VISIBLE REINFORCEMENT/PROJECTING AGGREGATE
custom_field_two
2
customer
1
datetime
2022-06-23T22:52:34-07:00
documentation
PRO PIPE
is_lateral_inspection
false