Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 3, 2022, 05:54 AM
  • 02 1387_02 1386_06032022_000754.mp4

Date
06/02/2022
W/O
956834
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00242
PipeID
P03905
Time
10:54 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10162
Sewer Name
02 CLOVERLAWN TRUNK
City
PARAMOUNT
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
31
Purpose
Routine Assessment
Project
WO_956834_TV02041_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
24 in.
Upstream MH
02 1387
Downstream MH
02 1386
Dir. of Survey
Downstream
Length Surveyed
338.7 ft.
Total Length
338.7 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 02 1387 to 02 1386
MH: 02 1387MH: 02 1386downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 13870 ft. MWM - Water Mark, 10 %of cross sectional area5.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start31.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"41.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"90.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"141 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"194 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"233.1 ft. FC - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES338.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish338.7 ft. AMH - Downstream Manhole, Survey Ends - 02 1386

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    31.8 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

    233.1 ft. - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
90.7TFC
338.6CM
0MWL
233.1FC
0AMH02 1387
31.8TB
194TFC
41.1TFC
5.6CM
141TFC
0MWM
338.7AMH02 1386

Properties (7)

additional_info
630074060222201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2022-06-02T22:54:09-07:00
documentation
PROPIPE
is_lateral_inspection
false