Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 29, 2022, 05:00 AM
  • J 0014_J 0012_07282022_223124.mp4

Date
07/28/2022
W/O
962068
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00060
PipeID
P11597
Time
10:00 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K10255
Sewer Name
J JOINT OUTFALL J - UNIT 2A
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
33
Purpose
Routine Assessment
Project
RFIR_WO_962068_TV08171_JUL2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Width
57 in.
Upstream MH
J 0014
Downstream MH
J 0012
Dir. of Survey
Downstream
Length Surveyed
480.7 ft.
Total Length
480.7 ft.
Structural Index
3
Structural Quick
5I2R
Structural Rating
432
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
436
Pipe schematic from manhole J 0014 to J 0012
MH: J 0014MH: J 0012downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 00140 ft. MWL - Water Level, 15 %of cross sectional area2 ft. MGO - General Observation - MAG COATING2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start240.5 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish480.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish480.5 ft. MGO - General Observation - CONNECTIONS IN MH AT BOTH 3 AND 9 O' CLOCK480.7 ft. AMH - Downstream Manhole, Survey Ends - J 0012

Observation photos (3)

  • General Observation - MAG COATING

    2 ft. - General Observation - MAG COATING

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
240.5SRV
2MGOMAG COATING
0MWM
2SRV
480.3SSS
2SSS
480.5MGOCONNECTIONS IN MH AT BOTH 3 AND 9 O' CLOCK
0AMHJ 0014
480.7AMHJ 0012
0MWL

Properties (7)

additional_info
630098072822201
custom_field_three
REINFORCEMENT VISIBLE
custom_field_two
2
customer
1
datetime
2022-07-28T22:00:45-07:00
documentation
PRO PIPE
is_lateral_inspection
false