B 0463A_B 0463_06132022_030706.mp4
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
133.6 ft. - Roots Medium Joint, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YESR, Start
212.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 217.6 | AMH | B 0463 |
| 212.7 | FM | — |
| 215.5 | SAP | — |
| 2 | DAGS | — |
| 0 | AMH | B 0463A |
| 147.8 | RMJ | — |
| 38.8 | CM | — |
| 215.5 | DAGS | — |
| 2 | SAP | — |
| 0 | MWL | — |
| 2 | CM | — |
| 0 | MWM | — |
| 133.6 | RMJ | — |
| 0 | MGO | CONNECTION AT MH 3 O'CLOCK |