- Date
- 06/13/2022
- W/O
- 957216
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00094
- PipeID
- P08976
- Time
- 2:07 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10145
- Sewer Name
- B JOINT OUTFALL B - UNIT 5D
- City
- PASADENA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- RFIR_WO_957216_TV16037_JUN2022
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 60 in.
- Upstream MH
- B 0463
- Downstream MH
- B 0462
- Dir. of Survey
- Downstream
- Length Surveyed
- 169.4 ft.
- Total Length
- 169.5 ft.
- Structural Index
- 3
- Structural Quick
- 3F2C
- Structural Rating
- 135
- O&M Index
- 2
- O&M Quick
- 412F
- O&M Rating
- 70
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 205
Pipe schematic from manhole B 0463 to B 0462 Observation photos (3)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

76.8 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start