Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 1, 2022, 09:19 AM
  • 02 0336_02 0335_06012022_032801.mp4

Date
06/01/2022
W/O
956794
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00259
PipeID
P02647
Time
2:19 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10161
Sewer Name
02 EAST COMPTON BOULEVARD RELIEF TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37
Purpose
Routine Assessment
Project
RFIR_WO_956794_TV02430_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
18 in.
Upstream MH
02 0336
Downstream MH
02 0335
Dir. of Survey
Downstream
Length Surveyed
347.9 ft.
Total Length
347.9 ft.
Structural Index
3
Structural Quick
4132
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 02 0336 to 02 0335
MH: 02 0336MH: 02 0335downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 03360 ft. MWL - Water Level, 5 %of cross sectional area16.4 ft. CM - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES51.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start161.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start161.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish341.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish347.9 ft. AMH - Downstream Manhole, Survey Ends - 02 0335

Observation photos (3)

  • Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

    16.4 ft. - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    51.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    161.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
341.3FM
0MWM
51.1CM
161.2FM
161.2CM
0AMH02 0336
16.4CM
347.9AMH02 0335
0MWL

Properties (7)

additional_info
630074053122201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-06-01T02:19:20-07:00
documentation
PROPIPE
is_lateral_inspection