Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 3, 2022, 07:49 AM
  • 02 0327_02 0326_06032022_020526.mp4

Date
06/03/2022
W/O
956794
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00259
PipeID
P02638
Time
12:49 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10163
Sewer Name
02 EAST COMPTON BOULEVARD RELIEF TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37
Purpose
Routine Assessment
Project
RFIR_WO_956794_TV02430_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
18 in.
Upstream MH
02 0327
Downstream MH
02 0326
Dir. of Survey
Downstream
Length Surveyed
436 ft.
Total Length
436 ft.
Structural Index
3
Structural Quick
4131
Structural Rating
13
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
13
Pipe schematic from manhole 02 0327 to 02 0326
MH: 02 0327MH: 02 0326downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 03270 ft. MWL - Water Level, 5 %of cross sectional area8.3 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES24.2 ft. CM - Crack Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES38.7 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES49.7 ft. CL - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES54.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start435.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish436 ft. AMH - Downstream Manhole, Survey Ends - 02 0326436 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (5)

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    8.3 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

    24.2 ft. - Crack Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES

    38.7 ft. - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    49.7 ft. - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    54.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
0MWM
436AMH02 0326
436MGOCONNECTION AT MH 9 O'CLOCK
0AMH02 0327
38.7FC
24.2CM
54.4FM
49.7CL
8.3CL
435.9FM
0MWL

Properties (7)

additional_info
630074060222202
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-06-03T00:49:51-07:00
documentation
PROPIPE
is_lateral_inspection
false