Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 21, 2022, 08:06 AM
  • 05 1271_05 1270_06212022_022018.mp4

Date
06/21/2022
W/O
956730
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00518
PipeID
P06483
Time
1:06 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10184
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_956730_TV05332_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
05 1271
Downstream MH
05 1270
Dir. of Survey
Downstream
Length Surveyed
338.9 ft.
Total Length
338.9 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
2
O&M Quick
2211
O&M Rating
5
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole 05 1271 to 05 1270
MH: 05 1271MH: 05 1270downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 12710 ft. MWM - Water Mark, 15 %of cross sectional area10.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start26.6 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"50.4 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"67.2 ft. TSC - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"130.4 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"142.4 ft. TSI - Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 1"152.3 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start246.7 ft. TSD - Tap Saddle Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6"266.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"336.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish336.2 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish338.9 ft. AMH - Downstream Manhole, Survey Ends - 05 1270338.9 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK338.9 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (4)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    10.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    142.4 ft. - Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    152.3 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    246.7 ft. - Tap Saddle Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (17)

DistanceCodeObservation
0MWL
336.2FM
67.2TSC
152.3RFJ
338.9AMH05 1270
142.4TSI
0AMH05 1271
338.9MGOCONNECTION AT MH 9 O'CLOCK
50.4TSC
246.7TSD
0MWM
26.6TS
266.9TFC
130.4TS
336.2RFJ
338.9MGOCONNECTION AT MH 3 O'CLOCK
10.7FM

Properties (7)

additional_info
630074062022202
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-06-21T01:06:20-07:00
documentation
PROPIPE
is_lateral_inspection