Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 21, 2022, 08:21 AM
  • 05 1270_05 1269_06212022_023518.mp4

Date
06/21/2022
W/O
956730
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00518
PipeID
P06482
Time
1:21 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10184
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_956730_TV05332_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
05 1270
Downstream MH
05 1269
Dir. of Survey
Downstream
Length Surveyed
338.6 ft.
Total Length
338.6 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
2
O&M Quick
3122
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
11
Pipe schematic from manhole 05 1270 to 05 1269
MH: 05 1270MH: 05 1269downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 12700 ft. MWM - Water Mark, 20 %of cross sectional area6.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start63.3 ft. TS - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"79.3 ft. TSI - Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2"151.3 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"171.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"222.9 ft. TS - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"222.9 ft. RML - Roots Medium Lateral, at 10 o'clock, 25 %, within 8 inches of joint: NO227.2 ft. TSI - Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2"258.6 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6"286.7 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"336.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish338.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK338.6 ft. AMH - Downstream Manhole, Survey Ends - 05 1269

Observation photos (5)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2"

    79.3 ft. - Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    171.2 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    222.9 ft. - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2"

    227.2 ft. - Tap Saddle Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2"

Observations (18)

DistanceCodeObservation
171.2TB
258.6TSC
0MGOCONNECTION AT MH 9 O'CLOCK
0MGOCONNECTION AT MH 3 O'CLOCK
222.9TS
6.1FM
0MWL
63.3TS
338.6MGOCONNECTION AT MH 9 O'CLOCK
227.2TSI
0AMH05 1270
286.7TSC
151.3TSC
222.9RML
0MWM
338.6AMH05 1269
336.1FM
79.3TSI

Properties (7)

additional_info
630074062022202
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-06-21T01:21:19-07:00
documentation
PROPIPE
is_lateral_inspection
false