Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 21, 2022, 08:52 AM
  • 05 1268_05 1267_06212022_025932.mp4

Date
06/21/2022
W/O
956730
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00518
PipeID
P06480
Time
1:52 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10184
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_956730_TV05332_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
05 1268
Downstream MH
05 1267
Dir. of Survey
Downstream
Length Surveyed
130.2 ft.
Total Length
130.2 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 05 1268 to 05 1267
MH: 05 1268MH: 05 1267downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 12680 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area10 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start55.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"63.3 ft. TSI - Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"119.2 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"130.2 ft. AMH - Downstream Manhole, Survey Ends - 05 1267130.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish130.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    10 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    63.3 ft. - Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

Observations (11)

DistanceCodeObservation
0AMH05 1268
0MGOCONNECTION AT MH 3 O'CLOCK
55.4TFC
130.2AMH05 1267
0MWM
130.2FM
119.2TSC
0MWL
63.3TSI
10FM
130.2MGOCONNECTION AT MH 9 O'CLOCK

Properties (7)

additional_info
630074062022202
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-06-21T01:52:15-07:00
documentation
PROPIPE
is_lateral_inspection
false