Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 1, 2022, 07:21 AM
  • 02 1033_02 1032_07012022_013825.mp4

Date
07/01/2022
W/O
957217
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00280
PipeID
P03607
Time
12:21 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10199
Sewer Name
02 MONTEBELLO CITY TRUNK
City
MONTEBELLO
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
14
Purpose
Routine Assessment
Project
WO_957217_TV02295_JUN2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
02 1033
Downstream MH
02 1032
Dir. of Survey
Downstream
Length Surveyed
330.6 ft.
Total Length
330.7 ft.
Structural Index
3
Structural Quick
3L2K
Structural Rating
313
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
315
Pipe schematic from manhole 02 1033 to 02 1032
MH: 02 1033MH: 02 1032downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 10330 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK.0 ft. MGO - General Observation - VERMIN (RAT) PRESENT @ APPROXIMATELY 10' DOWNSTREAM.0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK.2.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.7 ft. MGO - General Observation - MAG COAT33.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start53 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"79 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"81.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"102.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"120.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"122.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"180.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"182.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"216.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"218.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"250 ft. OBP - Obstacles External Pipe or Cable, 10 %of cross sectional area, from 10 to 02 o'clock - WALL DAMAGE: 10 TO 3 O'CLOCK WITH POSSIBLE PATCH ADDED.265.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"267.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"301.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"324.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"328.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish328.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish330.7 ft. AMH - Downstream Manhole, Survey Ends - 02 1032330.7 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK.

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Obstacles External Pipe or Cable, 10 %of cross sectional area, from 10 to 02 o'clock - WALL DAMAGE: 10 TO 3 O'CLOCK WITH POSSIBLE PATCH ADDED.

    250 ft. - Obstacles External Pipe or Cable, 10 %of cross sectional area, from 10 to 02 o'clock - WALL DAMAGE: 10 TO 3 O'CLOCK WITH POSSIBLE PATCH ADDED.

Observations (28)

DistanceCodeObservation
120.4TFC
102.2TFC
2.7SAV
0AMH02 1033
0MWL
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK.
182.7TFC
324.7TFC
33.8SSS
53TFC
180.2TFC
330.7AMH02 1032
79TFC
267.9TFC
301.4TFC
328.1SSS
0MGOVERMIN (RAT) PRESENT @ APPROXIMATELY 10' DOWNSTREAM.
330.7MGOACTIVE CONNECTION AT MH 9 O'CLOCK.
265.5TFC
122.8TFC
250OBPWALL DAMAGE: 10 TO 3 O'CLOCK WITH POSSIBLE PATCH ADDED.
81.7TFC
218.9TFC
328.1SAV
2.7MGOMAG COAT
0MWM
216.1TFC
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK.

Properties (7)

additional_info
630074063022213
custom_field_three
SPALLING, AGGREGATE VISIBLE.
custom_field_two
2
customer
1
datetime
2022-07-01T00:21:17-07:00
documentation
PROPIPE
is_lateral_inspection
false