- Date
- 06/17/2022
- W/O
- 957000
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00672
- PipeID
- P22249
- Time
- 2:44 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10178
- Sewer Name
- 18 BROADWAY TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- RFIR_WO_957000_TV18186_JUN2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 18 0268
- Downstream MH
- 18 0267A
- Dir. of Survey
- Downstream
- Length Surveyed
- 198.7 ft.
- Total Length
- 198.7 ft.
- Structural Index
- 3
- Structural Quick
- 4131
- Structural Rating
- 9
- O&M Index
- 2
- O&M Quick
- 2G00
- O&M Rating
- 78
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 87
Pipe schematic from manhole 18 0268 to 18 0267A Observation photos (6)

0 ft. - General Observation - COCKROACHES AT MH

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

52.7 ft. - Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES

169.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

193.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

198.7 ft. - General Observation - COCKROACHES AT MH