Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2022, 09:50 AM
  • 02 0032A_02 0032_06232022_040104.mp4

Date
06/23/2022
W/O
957123
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00234
PipeID
P03064
Time
2:50 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10189
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
BELLFLOWER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
39
Purpose
Routine Assessment
Project
RFIR_WO_957123_TV02341_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
8 in.
Upstream MH
02 0032A
Downstream MH
02 0032
Dir. of Survey
Downstream
Length Surveyed
178.8 ft.
Total Length
178.8 ft.
Structural Index
3
Structural Quick
4D2F
Structural Rating
164
O&M Index
2
O&M Quick
2F00
O&M Rating
70
Overall Index
2
Overall Quick
Overall Rating
234
Pipe schematic from manhole 02 0032A to 02 0032
MH: 02 0032AMH: 02 0032downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 02 0032A2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.6 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES31.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start32.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"143.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish176 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish176 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish176.9 ft. FM - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES178 ft. MGO - General Observation - ROACHES @ MH178.8 ft. AMH - Downstream Manhole, Survey Ends - 02 0032

Observation photos (3)

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    5.6 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    31.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES

    176.9 ft. - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
2DAGS
0MWM
143.6FM
178MGOROACHES @ MH
5.6CL
176DAGS
32.6TFC
0MGOROACHES @ MH
176SSS
178.8AMH02 0032
31.6FM
176.9FM
0MWL
2SSS
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
0AMH02 0032A

Properties (7)

additional_info
630074062222201
custom_field_three
FRACTURES/SPALLING
custom_field_two
2
customer
1
datetime
2022-06-23T02:50:30-07:00
documentation
PROPIPE
is_lateral_inspection
false