Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2022, 06:41 AM
  • 02 0012_02 0011_06232022_005535.mp4

Date
06/22/2022
W/O
957123
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00234
PipeID
P03038
Time
11:41 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10189
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Routine Assessment
Project
RFIR_WO_957123_TV02341_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
12 in.
Upstream MH
02 0011
Downstream MH
02 0012
Dir. of Survey
Upstream
Length Surveyed
394.2 ft.
Total Length
394.2 ft.
Structural Index
3
Structural Quick
4O2O
Structural Rating
468
O&M Index
2
O&M Quick
412O
O&M Rating
162
Overall Index
3
Overall Quick
Overall Rating
630
Pipe schematic from manhole 02 0011 to 02 0012
MH: 02 0011MH: 02 0012upstream0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Ends - 02 00120.2 ft. MGO - General Observation - ROACHES @ MH2.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish3.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish49.4 ft. TSC - Tap Saddle Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"89 ft. TS - Tap Saddle, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN211.2 ft. TS - Tap Saddle, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN247.6 ft. TSC - Tap Saddle Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"335.7 ft. TSI - Tap Saddle Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - OPEN367.2 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"391.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start392.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start392.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start394.2 ft. MWM - Water Mark, 50 %of cross sectional area394.2 ft. MWL - Water Level, 45 %of cross sectional area394.2 ft. AMH - Downstream Manhole, Survey Begins - 02 0011

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - OPEN

    58.5 ft. - Tap Saddle Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - OPEN

Observations (19)

DistanceCodeObservation
305.2TSOPEN
394.2MGOCONN @ MH 3 O'CLOCK/ACTIVE
2DAGS
2.6FM
2SSS
0MWM
344.8TSC
58.5TSIOPEN
394.2MGOCONN @ MH 9 O'CLOCK/ACTIVE
27TSA
392DAGS
0MWL
390.8FM
394.2AMH02 0012
146.6TSC
183TSOPEN
394MGOROACHES @ MH
392SSS
0AMH02 0011

Properties (7)

additional_info
630074062222201
custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2022-06-22T23:41:26-07:00
documentation
PROPIPE
is_lateral_inspection
false