Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2022, 04:44 AM
  • 02 0010_02 0009_06222022_230532.mp4

Date
06/22/2022
W/O
957123
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00234
PipeID
P03036
Time
9:44 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10189
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Routine Assessment
Project
RFIR_WO_957123_TV02341_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
15 in.
Upstream MH
02 0010
Downstream MH
02 0009
Dir. of Survey
Downstream
Length Surveyed
389 ft.
Total Length
389 ft.
Structural Index
2
Structural Quick
2O00
Structural Rating
162
O&M Index
2
O&M Quick
2O00
O&M Rating
156
Overall Index
2
Overall Quick
Overall Rating
318
Pipe schematic from manhole 02 0010 to 02 0009
MH: 02 0010MH: 02 0009downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 00102 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start21.2 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"79.4 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"89 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES94.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES147.6 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"147.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES160.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES189.8 ft. CS - Crack Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES208 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"272.5 ft. TS - Tap Saddle, at 12 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOIWN324.7 ft. TSC - Tap Saddle Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"387 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish387 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish389 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE389 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE389 ft. MGO - General Observation - ROACHES @ MH389 ft. AMH - Downstream Manhole, Survey Ends - 02 0009

Observation photos (6)

  • Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    21.2 ft. - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    89 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    94.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    147.6 ft. - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    160.3 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES

    189.8 ft. - Crack Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
389MGOCONN @ MH 3 O'CLOCK/ACTIVE
147.6TSA
21.2TSA
160.3CL
147.6DAGS
389MGOCONN @ MH 9 O'CLOCK/ACTIVE
0MWL
0MWM
387DAGS
387SSS
389MGOROACHES @ MH
2SSS
2DAGS
189.8CS
89CL
0AMH02 0010
94.6CL
79.4TSA
324.7TSC
208TSA
272.5TSUNKNOIWN
389AMH02 0009

Properties (7)

additional_info
630074062222201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-06-22T21:44:16-07:00
documentation
PROPIPE
is_lateral_inspection
false