Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2022, 05:41 AM
  • 02 0007_02 0006_06232022_000208.mp4

Date
06/22/2022
W/O
957123
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00234
PipeID
P03033
Time
10:41 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10189
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Routine Assessment
Project
RFIR_WO_957123_TV02341_JUN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
15 in.
Upstream MH
02 0007
Downstream MH
02 0006
Dir. of Survey
Downstream
Length Surveyed
355.4 ft.
Total Length
355.4 ft.
Structural Index
3
Structural Quick
473L
Structural Rating
357
O&M Index
2
O&M Quick
2M00
O&M Rating
142
Overall Index
2
Overall Quick
Overall Rating
499
Pipe schematic from manhole 02 0007 to 02 0006
MH: 02 0007MH: 02 0006downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 00072 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO, Start24.1 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES26.4 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"93.2 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"153.6 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"205.4 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"268.5 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"317 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish317 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start341.5 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"351.8 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish353 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish353 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish355.4 ft. AMH - Downstream Manhole, Survey Ends - 02 0006

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    317 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
0MWL
341.5TSA
351.8FM
317CM
153.6TSA
93.2TSA
2DAGS
268.5TSA
24.1DAGS
0MWM
205.4TSA
26.4TSA
0AMH02 0007
353SSS
353DAGS
2SSS
2.1CM
317FM
355.4AMH02 0006

Properties (7)

additional_info
630074062222201
custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2022-06-22T22:41:45-07:00
documentation
PROPIPE
is_lateral_inspection
false