Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2022, 07:40 AM
  • 02 0005_02 0132_06232022_014621.mp4

Date
06/23/2022
W/O
957123
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00234
PipeID
P03030
Time
12:40 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10189
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Routine Assessment
Project
RFIR_WO_957123_TV02341_JUN2022
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
15 in.
Upstream MH
02 0005
Downstream MH
02 0132
Dir. of Survey
Downstream
Length Surveyed
2.3 ft.
Total Length
2.3 ft.
Structural Index
3
Structural Quick
5131
Structural Rating
10
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
4
Overall Quick
Overall Rating
15
Pipe schematic from manhole 02 0005 to 02 0132
MH: 02 0005MH: 02 0132downstream0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/UNKNOWN0 ft. AMH - Upstream Manhole, Survey Begins - 02 0005N0 ft. MWL - Water Level, 100 %of cross sectional area0 ft. MWM - Water Mark, 100 %of cross sectional area2.3 ft. MSA - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH2.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES2.3 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES2.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

Observation photos (4)

  • Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

    2.3 ft. - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

    2.3 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
0MGOCONN @ MH 3 O'CLOCK/UNKNOWN
2.3MSAVIEW OF D/S SIPHON FROM U/S MH
2.3SAP
0AMH02 0005N
0MWL
2.3SRV
2.3SSS
0MWM

Properties (7)

additional_info
630074062222201
custom_field_three
AGGREGATE PROJECTING/SPALLING
custom_field_two
2
customer
1
datetime
2022-06-23T00:40:57-07:00
documentation
PROPIPE
is_lateral_inspection
false